Product characteristics |
Number of inputs and outputs |
Number of digital outputs: 1 |
Process connection |
M18 x 1,5 Internal thread |
Application |
Media |
Liquids; Gases |
Medium temperature [°C] |
-25...80 |
Pressure rating [bar] |
300 |
MAWP (for applications according to CRN) [bar] |
208 |
Liquids |
Medium temperature [°C] |
-25...80 |
Gases |
Medium temperature [°C] |
-25...80 |
Electrical data |
Operating voltage [V] |
18...36 DC |
Current consumption [mA] |
< 60 |
Protection class |
III |
Reverse polarity protection |
yes |
Power-on delay time [s] |
10 |
Inputs / outputs |
Number of inputs and outputs |
Number of digital outputs: 1 |
Outputs |
Total number of outputs |
1 |
Output signal |
switching signal; IO-Link; (configurable) |
Electrical design |
PNP |
Number of digital outputs |
1 |
Output function |
normally open / closed; (configurable) |
Max. voltage drop switching output DC [V] |
2.5 |
Permanent current rating of switching output DC [mA] |
250 |
Short-circuit protection |
yes |
Type of short-circuit protection |
yes (non-latching) |
Overload protection |
yes |
Measuring/setting range |
Liquids |
Setting range [cm/s] |
3...300 |
Greatest sensitivity [cm/s] |
3...100 |
Gases |
Setting range [cm/s] |
200...3000 |
Greatest sensitivity [cm/s] |
200...800 |
Accuracy / deviations |
Repeatability [cm/s] |
1...5 |
Note on repeatability |
for water 5...100 cm/s; 25 °C |
Factory setting |
|
Temperature drift [cm/s x 1/K] |
0.1; (for water 5...100 cm/s; 10...70 °C) |
Max. temperature gradient of medium [K/min] |
300 |
Switch point accuracy [cm/s] |
± 2...± 10; (for water 5...100 cm/s; 25 °C; Factory setting) |
Hysteresis [cm/s] |
2...5; (for water 5...100 cm/s; 25 °C; Factory setting) |
Reaction times |
Liquids |
Response time [s] |
1...2; (for a temperature gradient: 1 K/min) |
Gases |
Response time [s] |
1...10 |
Software / programming |
Adjustment of the switch point |
pushbuttons |
Interfaces |
Communication interface |
IO-Link |
Transmission type |
COM2 (38,4 kBaud) |
IO-Link revision |
1.1 |
SDCI standard |
IEC 61131-9 |
Profiles |
Smart Sensor: Process Data Variable; Device Identification |
SIO mode |
yes |
Required master port class |
A |
Process data analog |
2 |
Process data binary |
2 |
Min. process cycle time [ms] |
3 |
Supported DeviceIDs |
Type of operation |
DeviceID |
default |
54 |
|
Operating conditions |
Ambient temperature [°C] |
-25...80 |
Storage temperature [°C] |
-25...100 |
Protection |
IP 65; IP 67 |
Tests / approvals |
EMC |
DIN EN 61000-6-2 |
|
DIN EN 61000-6-3 |
|
|
Shock resistance |
DIN IEC 60068-2-27 |
50 g (11 ms) |
|
Vibration resistance |
DIN EN 60068-2-6 |
20 g (55...2000 Hz) |
|
MTTF [years] |
298 |
Mechanical data |
Weight [g] |
248.5 |
Dimensions [mm] |
M18 x 1.5 |
Thread designation |
M18 x 1.5 |
Material |
stainless steel (1.4404 / 316L); stainless steel (1.4301 / 304); PC; PBT-GF20; EPDM/X |
Materials (wetted parts) |
stainless steel (1.4404 / 316L); O-ring: FKM 80 Shore A |
Process connection |
M18 x 1,5 Internal thread |
Displays / operating elements |
Display |
Function |
10 x LED, three-color |
|
Remarks |
Pack quantity |
1 pcs. |
Electrical connection |
Connection |
Connector: 1 x M12 |