Data de livrare: Vineri, 19.12.2025
| Applied standards | EN ISO 13849-1, EN 60947-5-1, EN ISO 14119 |
|---|---|
| Enclosure | thermoplastic, glass-fibre reinforced, impact resistant, self-extinguishing UL 94 V-0 |
| Switch type | type 1 |
| Coding level | no coding |
| Degree of protection | IP 66 to IEC/EN 60529 |
| B10d (10 % load) | 2 million |
| TM | max. 20 years |
| Contact material | silver |
| Switching system | slow action, positive break NC contacts |
| Switching elements | 2 NC/1 NO contact, type Zb |
| Connection | cable 6 x AWG 26 |
| Cable cross-section | 6 x 0.14 mm² |
| Rated impulse withstand voltage Uimp | 4 kV |
| Rated operating isolation voltage Ui | 250 V |
|---|---|
| Conventional thermal current Ithe | 6 A |
| Rated operating current/voltage Ie/Ue | 6 A/250 VAC; 0.25 A/230 VDC |
| Utilisation category | AC-15; DC-13 |
| Short-circuit protection | 6 A gG/gN fuse |
| Ambient temperature | –40 °C … +75 °C |
| Mechanical life | > 1 million operations |
| Operation cycles | max. 1800/h |
| Repeat accuracy of switching points | ± 0.1 mm |
| Contact opening | max. 2 x 4 mm |
| Weight | 111 g |